Schiller AT 2 Cardiovit ECG EKG w/ Interpretation
Schiller AT 2 Cardiovit ECG EKG w/ Interpretation Schiller AT 2 Cardiovit ECG EKG w/ Interpretation

Schiller AT 2 Cardiovit ECG EKG w/ Interpretation

Be the first to review this product

The AT-2 is a low cost 6/12 channel ECG system with performance features previously only available in high priced systems. The AT-2 provides A4 reports within seconds - at the touch of a button.
  • 6/12-channel representation of all 12 simultaneously acquired leads
  • Automatic and manual mode
  • Full size 8" x 11" reports (A4)
  • Integrated rechargeable battery lasts for up to 400 recordings
  • Single button operation
  • Built-in thermal printer
  • Computerised ECG interpretation program
  • CE labelled
  • Meets or exceeds U.S. and international quality standards
  • Portable at only 4.8 kg / 11 lbs
  • Item Name Schiller AT 2 Cardiovit ECG EKG w/ Interpretation
    Specifications System:
  • Dimensions: 400 x 330 x 101 mm, approx. 4.8 kg
  • Power supply requirements: 220 – 240 V (nominal), 50/60 Hz or 100 – 115 V (nominal), 50/60 Hz independent operation with built-in rechargeable battery,
  • LED indication for mains and battery, built-in charger unit
  • Power consumption: Max. 28 VA
  • Battery charging time: 15 hrs. from a completely discharged battery, 3 hrs. to 60 % capacity
  • Battery capacity: 6 hrs. of normal use or 400 automatic ECG printouts
  • Frequency range of digital recorder: 0 Hz – 150 Hz (IEC/AHA)
  • Patient input circuitry: Fully floating and isolated, defibrillation protected (only with original SCHILLER patient cable)
  • Control panel and keyboard: User-friendly key pad, LED indicators
  • LED indicators: - Lead group - Mains connected - Battery operation and low battery (indicator flashes) - Paper tray empty or jammed - Filter status (on/off) - Loose electrodes Leads:
  • 12 simultaneous leads: Standard / Cabrera
  • Myogram (muscle tremor) filter: Adjustable at 25 or 35 Hz (also for copy function)
  • Line frequency filter: Distortion-free suppression of superimposed
  • 50 or 60 Hz sinusoidal interferences by means of adaptive digital filtering
  • ECG amplifier: - Simultaneous, synchronous recording of all 9 active electrode signals (= 12 leads) - Sampling frequency: 1000 Hz - Pacemaker detection: Amplitudes from ± 2 to ± 700 mV and pulse widths from 0.1 to 2.0 ms Printing (built-in thermal printer):
  • Paper speed: 5 / 25 / 50 mm/s (manual printout)
  • Sensitivities: 5 / 10 / 20 mm/mV, either automatically adjusted or manually selected
  • Chart paper: Thermoreactive, Z-folded, A4 (letter size), perforation each page, approx. 60 m
  • Printing process: - High-resolution thermal printhead - 8 dots per mm / 200 dots per inch (amplitude axis) - 40 dots per mm / 1000 dots per inch (time axis) @ 25 mm/s Automatic lead programs:
  • 6/12 channel representation of 12 simultaneously acquired standard leads on one or two pages, full letter size (A4)
  • Data record: - With optional measurement and interpretation program: ECG measurement results (intervals, amplitudes, electrical axes), average complexes with optional measurement reference markings, ECG interpretation statements - Various format possibilities Recording tracks:
  • 6 channels, positioned at optimal width on 200 mm, automatic baseline adjustment
  • Norms:
  • Safety standard: CF according to IEC/EN 60601-1 and IEC/EN 60601-2-25, CSA C22.2 No. 601.1-M90, UL 2601-1
  • Protection class: I according to IEC/EN 60601-1 (with internal battery)
  • Classification: lla according MDD 93/42/EEC
  • Conformity: according to MDD 93/42/EEC
  • Environmental conditions: - Temperature, operating: 10° to 40° C / 50° to 104° F - Temperature, storage: -10° to 50° C / 14° to 122° F - Relative humidity, operating: 25 to 95 % (non-condensing) - Pressure, operating: 700 to 1060 hPa Patient leakage current: < 5 μA Scope of delivery:
  • CARDIOVIT AT-2 basic unit with 12-lead Resting ECG
  • Accessories: - 10-lead patient cable - 500 disposable electrodes or reusable electrode set - Snapclip adapter for disposable electrodes - Power cable - 2 pkg. of recording paper - Operating manual - Cart (optional) Software option:
  • Automatic measurement and interpretation program for Resting ECGs (intervals, amplitudes, electrical axes, average complexes with optional measurement reference markings)
  • Technical data are subject to change without notice.
  • Brand Schiller
    Free Shipping Yes
    Warning N/A
    User Manual N/A
    Brochure Brochure (pdf)
    MSDS N/A

    You may also be interested in the following product(s)

    Schiller ECG/EKG Recording Paper for CS-200 AT 2 Series

    Schiller ECG/EKG Recording Paper for CS-200 AT 2 Series

    Starting at: $18.95

    Covidien / Kendall Resting ECG Electrodes

    Covidien / Kendall Resting ECG Electrodes

    Starting at: $103.95

    Nikomed Resting ECG Electrodes 500/BX

    Nikomed Resting ECG Electrodes 500/BX

    Starting at: $24.95

    ECG Alligator Clip Adapter

    ECG Alligator Clip Adapter

    Starting at: $29.95

     
  • OR
    SKU Image Item Name PKG Availability Price Qty
    9.020000C AT-2 w/ Interpretation AT-2 w/ Interpretation 1/EA

    Always in Stock - Ships Immediately

    $2,195.95